Updates to STIS NUV Dark Calibration
概要
We present new superdark calibration files (DARKFILEs) and a new dark correction table (TDCTAB) for use with data taken by the Space Telescope Imaging Spectrograph near-ultraviolet microchannel array (STIS NUV-MAMA) detector for HST Cycle 19 onward. These superdarks include 12 years of NUV dark exposures and make use of an updated temperature scaling equation developed in 2013 to more accurately characterize the dark rate. In tested datasets, the new superdarks provide an average 3% increase in…